Distancing:
One inch spacer attached
Readout:
3-1/2 digit LCD, automatically displays measured voltage.
Polarity:
Automatic, positive implied, negative polarity indication
Zero:
Semi-Automatic, "Push to Zero" Feature
Response:
Display updates three times per second
Low Battery Indication:
"BAT" is displayed when voltage is too low for proper function
Hold indication:
The "HOLD" indication appears on the LCD when in hold mode
Measurement Ranges:
@1 inch: 0-20,000 volts in 100 volt increments
@1/10 inch: 0-2,000 volts in 10 volt increments
Extended Ranges:
@ 4 inches: ± 40,000 volts (multiply reading x 2)
@ 6.5 inches: ± 60,000 volts (multiply reading x 3)
@ 8.5 inches: ± 80,000 volts (multiply reading x 4)
Accuracy:
Better than ± 10%
Grounding Path:
Through conductive case and snap on back
Battery SavRTM Timeout:
Typically 90 seconds, automatic shut off
Power:
One (1) standard 9-volt battery, PROCELL, Eveready #216 (NEDA 1604, JIS 006P,
IEC 6F22)Eveready #216
Battery Life:
200 hours typical
Dimensions:
4.2 inches x 2.4 inches x .9 inches
Weight:
5 oz. (142 gm)