Prostat Corporation
PDS-510 HBM Discharge Simulator
HBM Simulator used to test devices in compliance with ANSI/ESDA/JEDEC JS-001
 
  • Low cost two-pin tester for HBM
  • Portable and battery operated
  • Built-in DC power supply up to 4,000 VDC
  • Ideal for getting a good indication of ESD sensitivity of a device
  • Meets the waveform requirements of ANSI/ESDA/JEDEC JS-001
  • Incudes leads and grounding accessories
 

Assistance


 



The PSD-510 is a low cost, light weight, battery powered Human Body Model (HBM) simulator designed to help customers determine the HBM ESD sensitivity of a device in accordance with ANSI/ESDA/JEDEC JS-001.

Unlike most commercial testers that come with a test head, the PDS-510 is a manual two pin tester which means that only two pins at a time can be tested. The user must design a way to connect the PDS-510 to the pins under test. In addition, they must have a way to check for damage to the device either by using a curve tracer or functional tester. HBM data collected using the PDS-510 can be used for data sheet reporting.

The PDS-510 can also be used to obtain a general idea of the Machine Model (MM) and Charged Device Model (CDM) ESD sensitivity of a device using the precision built-in DC power supply that can be used to charge items up to 4,000 VDC. The power supply is used to charge other fixtures that can deliver an external MM/CDM pulse to the device or charge a plate similar to classical CDM testing.

The PDS-510 comes complete with a universal battery charger, test leads and grounding accessories. A certificate of calibration is also included.

If you are looking to test Shielded Bags per ANSI/ESD STM11.31, refer to the PBT-531 Shielded Bag Test Kit.